YLG-0.30 Marine Hydrophore Tank
[Search Related Products]
1.Technical Requirements:
1). Flange Standard£ºCB/T46-1999 PN1.0;
2). The shell cover thickness including the forming thinning;
3). The system including security settings;
4). Pipes and support same as the drawings.
2. Outer Joint:
Mark |
Name |
Size |
Standard |
a |
relief outlet |
3/4' |
|
b |
Water Inlet |
DN32 |
CB/T46-1999 PN1.0 |
c |
Compressor Air Inlet |
3/8' |
CB*53-80 |
d |
Water Outlet |
DN32 |
CB/T46-1999 PN1.0 |
3. Design Datas:
Working Pressure |
0.6Mpa |
Design Pressure |
0.7Mpa |
Working Temp. |
0~45¡æ |
Design Temp. |
50¡æ |
Main Materials |
CCS-B/SS304/SS316 |
corrosion allowance |
0.75mm |
welded joint coefficient |
0.6 |
Capacity |
0.3m³ |
The relief valve pressure jump |
0.63MPa |
G.W. |
265 Kgs (with standard export wooden case) |
N.W. |
215 Kgs |
4. Certificate: