hiseamarine

YLG-0.30 Marine Hydrophore Tank

[Search Related Products]

YLG-0.30 Marine Hydrophore Tank

1.Technical Requirements:

1). Flange Standard£ºCB/T46-1999 PN1.0;
2). The shell cover thickness including the forming thinning;
3). The system including security settings;
4). Pipes and support same as the drawings.

2. Outer Joint:

Mark

Name

Size

Standard

a

relief outlet

3/4'

b

Water Inlet

DN32

CB/T46-1999 PN1.0

c

Compressor Air Inlet

3/8'

CB*53-80

d

Water Outlet

DN32

CB/T46-1999 PN1.0

3. Design Datas:

Working Pressure

0.6Mpa

Design Pressure

0.7Mpa

Working Temp.

0~45¡æ

Design Temp.

50¡æ

Main Materials

CCS-B/SS304/SS316

corrosion allowance

0.75mm

welded joint coefficient

0.6

Capacity

0.3m³

The relief valve pressure jump

0.63MPa

G.W.

265 Kgs (with standard export wooden case)

N.W.

215 Kgs